protective coatings | innovations
Transcript
protective coatings | innovations
PROTECTIVE COATINGS | INNOVATIONS © Belzona PREVENTING CHEMICAL SPILLS BY PROTECTING SECONDARY CONTAINMENT AREAS: CHEMICAL RESISTANT CRACK-BRIDGING TECHNOLOGY Prevenire il versamento di sostanze chimiche proteggendo le aree di contenimento secondario: tecnologia di crack-bridging resistente agli agenti chimici T Opening picture: Buncefield fire Foto d’apertura: l’incendio di Buncefield. 52 anks and drums containing hazardous and flammable liquids require secondary and tertiary protection to prevent potential accidents, such as the Buncefield fire in 2006 (Ref. Opening Picture). Lessons learned from that accident were translated into effective and practical guidance that industry would implement as rapidly as possible. This guidance, titled “Safety and environmental standards for fuel storage sites” (Part 42, p 16), suggests that insufficient secondary containment contributed to the accident progression and states: “Bund wall and floor construction and penetration joints should be leak-tight. Surfaces should be free from any cracks, discontinuities and joint failures that may allow relatively unhindered liquid trans-boundary migration. As a priority, existing bunds should be checked and any damage or disrepair, which may render the structure less than N. 18 - 2016 JUNE - ipcm® Protective Coatings S erbatoi e fusti contenenti liquidi pericolosi e infiammabili richiedono una protezione secondaria e terziaria per prevenire potenziali incidenti, come l’incendio di Buncefield del 2006 (rif. foto d’apertura). Le lezioni imparate da quell’incidente si sono tradotte in una guida pratica efficace che l’industria ha implementato il più rapidamente possibile. Questa guida, intitolata “Standard di sicurezza e ambientali per i siti di stoccaggio del combustibile” (parte 42, p. 16), suggerisce che un contenimento secondario insufficiente ha contribuito all’evolversi dell’incidente e dichiara: “Il bacino di contenimento, la pavimentazione e i giunti devono essere a tenuta stagna. Le superfici dovrebbero essere prive di fratture, discontinuità e giunzioni danneggiate che possano far tracimare i liquidi relativamente senza ostacoli. Come priorità, i contenimenti già costruiti dovrebbero essere controllati e ogni danno o stato di degrado che possa inficiarne la tenuta stagna dovrebbe essere riparato”. La direttiva Seveso II dell’Unione Europea contiene un databa- Marina Silva Belzona Polymerics Ltd, Harrogate UK, [email protected] leak-tight, should be remedied.” The EU Seveso II Directive holds a database of reported chemical related accidents and near misses of its member organisations. In July 1999, 16.561 tonnes of 30% solution of sodium cyanide at a top-tier COMAH site was released through a leak in the tank to its bund. Of that quantity only 4.260 tonnes were recovered with the remaining material lost to the ground and water. Recommendation again called for improvements to the secondary containment area. The entry does not state what level of protection this bund had if any, but it can be assumed that since three quarters of the leaked material escaped the bund, the protection was either not there, its chemical resistance was insufficient, or this protection developed cracks allowing for the chemicals to seep through the bund. se degli incidenti e dei potenziali incidenti conosciuti dei suoi membri relativi alle sostanze chimiche. A luglio 1999, presso un sito COMAH top-tier, 16.561 tonnellate di una soluzione di cianuro di sodio al 30% è stata rilasciata attraverso una perdita del serbatoio e ha raggiunto il bacino di contenimento. Del totale, soltanto 4.260 tonnellate sono state recuperate, mentre il materiale restante si è disperso nella terra e nell’acqua. Anche in questo caso, erano stati raccomandati interventi di miglioramento dell’area di contenimento secondario. La nota non dichiara quale fosse il livello di protezione (e se ce ne fosse alcuna) del bacino di contenimento ma, poiché tre quarti del materiale fuoriuscito l’hanno superato, è possibile presumere che non ci fosse alcuna protezione, che la sua resistenza chimica non fosse sufficiente oppure che nella protezione si fossero sviluppate fratture consentendo alle sostanze di filtrare attraverso il bacino. National Codes of Practice Following dangerous occurrences varying in scale from minor near misses to those with catastrophic consequences, many countries have adopted codes of practice directed at installing and maintaining suitable secondary containment. US Environmental Protection Agency (EPA) for instance refers to stationary tank bunds in the Resource Conservation and Recovery Act (RCRA) Subpart J, Tank Systems (40 CFR 264. 193). “Secondary containment systems must be: (b, 1) Designed, installed, and operated to prevent any migration of wastes or accumulated liquid out of the system to the soil, ground water, or surface water at any time during the use of the tank system; and (b, 2) Capable of detecting and collecting releases and accumulated liquids until the collected material is removed.” To meet these requirements, the secondary containment area must be: (C, 1) “Constructed of or lined with materials that are compatible with the waste(s) to be placed in the tank system […]” and (e, 1, iii) “free of cracks or gaps”. In the UK, Control of Pollutions Regulations 2001 also states that “the container must be situated within a secondary containment system which satisfies the following requirements […] (c) its base and walls must be impermeable […]”. Secondary containment areas are typically constructed using concrete, because it is cost-effective and provides good structural strength. However, due to its porosity, concrete can be easily permeated and has poor chemical resistance, making it susceptible to deterioration through chemical attack. In addition, concrete is highly prone to cracking due to substrate movement and freeze-thaw cycles. Codici di regolamentazione nazionali A seguito di pericolosi accadimenti, variabili in una scala da incidenti minori, incidenti sfiorati fino a incidenti con conseguenze catastrofiche, molti Paesi hanno adottato dei codici di regolamentazione diretti all’installazione e alla manutenzione di un contenimento secondario adeguato. L’agenzia statunitense Environmental Protection Agency (EPA), per esempio, fa riferimento ai bacini per cisterne fisse nel Resource Conservation and Recovery Act (RCRA, Subpart J, Tank Systems, 40 CFR 264. 193). “I sistemi di contenimento secondari devono essere: (b, 1) Progettati, installati e utilizzati per prevenire la migrazione di scorie o liquidi accumulati fuori dal sistema fino a terreno, falde acquifere, acque superficiali, in ogni momento in cui la cisterna sia utilizzata”; e (b, 2) “In grado di rilevare e raccogliere perdite e liquidi accumulati finché il materiale raccolto non sia rimosso”. Per soddisfare questi requisiti, l’area di contenimento secondaria deve essere: (C, 1) “Costituita oppure rivestita con materiali compatibili con le scorie presenti nel sistema di stoccaggio […]” e (e, 1, iii) “priva di fratture o aperture”. Nel Regno Unito, la normativa del 2001, Control of Pollutions Regulations, dichiara inoltre che “il contenitore deve essere situato all’interno di un sistema secondario di contenimento che soddisfi i seguenti requisiti […] (c) la sua base e le sue pareti devono essere impermeabili […]”. Le aree di contenimento secondarie sono solitamente costruite in cemento, poiché è efficiente dal punto di vista dei costi e offre una buona resistenza strutturale. Tuttavia, a causa della sua porosità, il cemento può essere facilmente permeato e ha una bassa resistenza chimica, fattore che lo rende suscettibile al deterioramento per attacco chimico. Inoltre, il cemento si frattura facilmente a causa del movimento del substrato e dei cicli di congelamento-scongelamento. ipcm® Protective Coatings - 2016 JUNE - N. 18 53 1 1 Crack in concrete. Una frattura nel cemento. 2 ASTM D412 testing. Test ASTM D412. 54 © Belzona © Belzona PROTECTIVE COATINGS | INNOVATIONS 2 Barrier Coatings for Secondary Containment Areas I rivestimenti-barriera per le aree di contenimento secondarie As concrete does not address the requirement for chemical resistance, an additional barrier atop is needed to prevent potential spillages from permeating the secondary containment area. Over the years, a variety of solutions have been trialled, from bitumen based paints to epoxy resin based systems. The right solution would depend on the type of media stored within the tank, size of the containment area, expected traffic and weather conditions, among others. Where the highest chemical resistance is required in case of extremely aggressive chemicals, such as concentrated mineral acids, alkali, amines and alcohols; solventfree epoxy novolac resin based coatings are typically specified. The drawback of these coatings, however, has long been associated with the very feature that made them chemically resistant - their rigidity. The chemical reaction between the base and solidifier creates an almost impenetrable “physical barrier”. Subsequently, once hardened and cured, these epoxy systems become completely liquid-impermeable and will have excellent resistance to immersion and exposure to a wide range of oil and chemical spillages. Rigidity of these coatings, however, also makes them inflexible and not best suited for heavy trafficked areas or in cases where the underlying concrete develops cracks. Concrete can develop cracks for many reasons, from excessive loading, to thermal expansion/contraction or Poiché il cemento non risponde al requisito di resistenza chimica, è necessario che su di esso sia presente un’ulteriore barriera per prevenire che potenziali fuoriuscite permeino l’area di contenimento secondario. Nel corso degli anni sono state testate diverse soluzioni, dalle vernici a base di bitume fino ai sistemi con resine epossidiche. La soluzione corretta dipende, per esempio, dal tipo di sostanza stoccata all’interno del serbatoio, dalla dimensione dell’area di contenimento, dal traffico e dalle condizioni metereologiche previste. Laddove è necessaria una resistenza chimica elevata, in caso di stoccaggio di sostanze chimiche estremamente aggressive come acidi minerali concentrati, alcali, ammine e alcoli, sono solitamente specificati rivestimenti a base di resine epossidiche novolac privi di solvente. Lo svantaggio di questi rivestimenti, tuttavia, è stato a lungo associato proprio con la caratteristica che li rende resistenti agli attacchi chimici: la loro rigidità. La reazione chimica tra la base e il solidificatore crea una “barriera fisica” quasi impenetrabile. Di conseguenza, una volta induriti e polimerizzati, questi sistemi epossidici diventano completamente impermeabili ai liquidi e possiedono un’eccellente resistenza all’immersione e all’esposizione a un’ampia gamma di versamenti, da oli a sostanze chimiche. La rigidità di questi rivestimenti, tuttavia, li rende anche non flessibili e inadatti ad aree altamente trafficate, o nei casi in cui il cemento sottostante sviluppi fratture. Il cemento può sviluppare fratture per molte ragioni: dal carico eccessivo, all’espansione/contrazione termica o durante i cicli di congelamento/scongelamento, che por- N. 18 - 2016 JUNE - ipcm® Protective Coatings Th fo 27 – Tea with WindE The c WindE QHWZR Marina Silva Belzona Polymerics Ltd, Harrogate UK, [email protected] during freeze/thaw cycles, which lead to the concrete’s movement and settlement (Fig. 1). A rigid coating would crack with the concrete, thus terminating chemical protection in case of a spill. Recent advancements in polymer technology have resulted in the development of a hybrid epoxy coating, which combines high cross-linking with rubbery domains in the polymer chain, giving the coating a desired degree of flexibility. tano al movimento e assestamento del cemento (fig. 1). Un rivestimento rigido, quindi, si fratturerebbe insieme al cemento ponendo fine alla protezione chimica in caso di versamento. I recenti progressi nella tecnologia dei polimeri hanno portato allo sviluppo di un rivestimento epossidico ibrido, che unisce un’elevata reticolazione con domini gommosi nella catena polimerica, dando alla soluzione il grado desiderato di flessibilità. Nuovo materiale sviluppato New Material Development One of the recently introduced coatings to successfully incorporate these features comes from Belzona Polymerics Ltd and is known as Belzona 4361. To determine the coating’s crack-bridging abilities, Belzona 4361 was first tested for elongation, measured in accordance with ASTM D412. When cured at 20°C/68°F, Belzona 4361’s residual elongation was recorded at 20%, which would be sufficient to bridge a typical crack. To ensure the coating maintains its flexibility at low temperatures, a mandrel bend test in accordance with ASTM D552 was also performed (Fig. 2), resulting in a pass at temperatures down to 0°C/32°F. To further test this coating’s crack-bridging abilities, Uno dei rivestimenti recentemente introdotti per incorporare con successo queste caratteristiche è di Belzona Polymerics Ltd, conosciuto con il nome di Belzona 4361. Per determinare le capacità di crack-bridging del rivestimento, questa soluzione è stata sottoposta per prima cosa al test di allungamento, misurato secondo lo standard ASTM D412. Quando polimerizza a 20°C/68°F, l’allungamento residuo di Belzona 4361 è stato valutato al 20%, sufficiente a coprire una frattura tipica. Per assicurare che il rivestimento mantenga la sua flessibilità a basse temperature, è stata eseguita anche la prova di piegatura con mandrino secondo lo standard ASTM D552 (fig. 2), superata a temperature inferiori a 0°C/32°F. Per testare ulteriormente le capacità di questo rivestimento The world‘s leading expo for wind energy 27 – 30 SEPTEMBER 2016 Teaming up with WindEnergy Hamburg is the global meeting point for onshore and offshore experts. The combination of the world’s leading expo for wind energy in conjunction with WindEurope‘s leading industry conference represents a one-stop shop for business, QHWZRUNLQJSROLF\PDNHUVDQGWKHVFLHQWLÀFFRPPXQLW\6DYHWKHGDWH in co-operation with ipcm® Protective Coatings - 2016 JUNE - N. 18 55 3 3 Containment area. Area di contenimento. 4 Bund protected with Belzona 4361. Bacino protetto con Belzona 4361. 56 4 Belzona 4361 was submitted for a long-term testing at the University of Stuttgart, Germany. The university carries out testing to award a German Federal Water Act (WHG) Approval which is part of a German water law for protecting surface water and groundwater. Only chemical containment coatings with WHG Approval can be used in areas where strict regulations are in place, in order to protect ground water against chemical pollutants. The testing takes two years to complete and consists of a combination of crack-bridging, chemical resistance and aging tests. Crack-bridging tests are first performed by creating a crack within the concrete and ensuring the coating remains intact. This is followed by chemical resistance testing where the chemical is positioned onto the test coating so that the crack in the concrete is directly underneath. Signs of chemical attack are visually observed, in particular to see if the chemical reagent attacks the test coating severely enough to penetrate through the crack due to the reduction in film thickness over the crack. To replicate real life exposure or aging, the coated test blocks are stored in damp sand and placed outdoors. After six months and two years respectively of aging exposure, crack-bridging and chemical resistance tests are repeated. Belzona 4361 passed the crack-bridging and chemical resistance tests after six months of aging exposure, which will be repeated again to complete the two year’s testing. WHG presents rigorous independent testing and the results will be equally relevant in Europe and globally. Chemical resistance was tested by coating rods and immersing them in specified chemicals for a period of up to 12 months. N. 18 - 2016 JUNE - ipcm® Protective Coatings © Belzona © Belzona PROTECTIVE COATINGS | INNOVATIONS crack-bridging, Belzona 4361 è stato sottoposto a una prova a lungo termine presso l’Università di Stoccarda, Germania. L’università effettua le prove per assegnare la certificazione tedesca Federal Water Act (WHG), parte della legge tedesca per la protezione dell’acqua di superficie e delle falde acquifere. Soltanto i rivestimenti per il contenimento chimico con la certificazione WHG possono essere utilizzati nelle aree con regolamentazioni severe, con l’obiettivo di proteggere le falde dagli inquinanti chimici. Il test è stato completato in 2 anni e consiste in una combinazione di crack-bridging, resistenza chimica e prove d’invecchiamento. Le prove di crack-bridging sono eseguite per prime con la creazione di una frattura all’interno del cemento e verificando che il rivestimento resti intatto. Questo test è seguito dalle prove di resistenza chimica, nelle quali delle sostanze sono posizionate sul rivestimento campione in modo che la frattura nel cemento si trovi esattamente sotto. Si possono così osservare visivamente i segni di attacco chimico, in particolare per vedere se il reagente attacca abbastanza duramente il campione fino a penetrare attraverso la frattura a causa della diminuzione dello spessore del film al di sopra di essa. Per replicare l’esposizione reale o l’invecchiamento, i blocchi di prova rivestiti sono stoccati in sabbia umida e posti all’esterno. Dopo rispettivamente sei mesi e due anni di esposizione all’invecchiamento, i test di crack-bridging e resistenza chimica sono stati ripetuti. Belzona 4361 ha superato le prove di crackbridging e resistenza chimica dopo 6 mesi di esposizione all’invecchiamento, che saranno ripetute per completare la prova di due anni. WHG effettua test indipendenti rigorosi e i risultati sono validi allo stesso modo in Europa e nel resto del mondo. La resistenza chimica è stata testata rivestendo delle barre e immergendole in specifiche sostanze chimiche per un periodo fino a 12 mesi. Marina Silva Belzona Polymerics Ltd, Harrogate UK, [email protected] Table 1 illustrates obtained results for some of the tested chemicals. La tabella 1 illustra i risultati ottenuti con alcune delle sostanze utilizzate nelle prove. Chemical Belzona 4361 length of resistance 93% Sulphuric Acid 52 weeks and beyond 37% Hydrochloric Acid 52 weeks and beyond 43% Phosphoric Acid 4 weeks 25% Phosphoric Acid 39 weeks 10% Acetic Acid 1 week 2% Acetic Acid 52 weeks and beyond 25% Ammonia 4 weeks Ethyl Acetate 52 weeks and beyond Ethanolamine 1 week Oil, Petrol and Diesel 52 weeks and beyond Ethanol 52 weeks and beyond Methanol 17 weeks Table 1. Chemical Resistance of Belzona 4361 The coating is perfectly suitable to resist aggressive chemicals, as protection is only required to last until the leaked chemical can be recovered from the bund. Best practice reports in some countries do not specify a universal length of time the coating needs to resist the spilled chemical and some documents state 72 hours as an acceptable length of protection, see the U.S Environmental Protection Agency proposal, 40 CFR 112.7(c). Tabella 1: resistenza chimica di Belzona 4361. Il rivestimento è perfettamente adeguato per resistere alle sostanze chimiche aggressive, poiché la protezione deve durare soltanto fino a quando il versamento è stato recuperato dal bacino. In alcuni Paesi, i rapporti sulle best practice non specificano in modo universale il periodo di resistenza del rivestimento alle sostanze, mentre alcuni documenti riportano 72 ore come una durata di protezione accettabile (U.S Environmental Protection Agency proposal, 40 CFR 112.7(c)). Protezione chimica in azione Chemical Protection in Action Following its introduction in 2015, Belzona 4361 has been applied to protect the most critical assets. A secondary containment area in a Missouri, U.S. power plant was coated with Belzona 4361 after the existing chemical protection had failed. The bund in place to contain spillages from a 93% sulphuric acid tank (Fig. 3) experienced splashes, spills and poor clean-up procedures, in addition to movement which resulted in small gaps forming between the floor and bottom of the wall inside the containment area. The power station has already been using a variety of Belzona materials ever since six years ago Belzona Gateway Inc, the local Belzona Distributor, solved a major leak problem bringing their water treatment plant back in service. It then came as no surprise that this long standing customer turned to their local Belzona representative for a solution. After assessing the problem, Belzona Gateway proposed to use Belzona 4361 due to its excellent chemical resistance, flexibility and good adhesion facilitating long-term sealing between the bund’s wall and floor (Fig. 4). The application was carried out in March 2015 A seguito della sua introduzione nel 2015, Belzona 4361 è stato applicato per proteggere gli asset più critici. In Missouri (USA), l’area di contenimento secondario di una centrale elettrica è stata verniciata con Belzona 4361 dopo il fallimento del precedente sistema di protezione dalle sostanze chimiche. Il bacino di contenimento, installato per contenere i versamenti di un serbatoio di acido solforico al 93% (fig. 3), ha mostrato perdite, versamenti e procedure di pulizia insufficienti, oltre a movimenti che hanno causato la formazione di piccoli vuoti tra il pavimento e il fondo della parete all’interno dell’area di contenimento. La centrale elettrica utilizzava diversi prodotti Belzona già da 6 anni, quando Belzona Gateway Inc, il distributore locale di Belzona, aveva risolto un grave problema di versamento riportando in servizio il loro impianto di trattamento delle acque. Non è dunque una sorpresa se questo cliente di lungo corso si è rivolto al rappresentante locale di Belzona per una soluzione. Dopo aver valutato il problema, Belzona Gateway ha proposto l’utilizzo di Belzona 4361 per le sue eccellenti caratteristiche di resistenza chimica, flessibilità e buona adesione, che facilitano la sigillatura a lungo termine tra la parete e il pavimento del bacino (fig. 4). L’applicazione è stata effettua- ipcm® Protective Coatings - 2016 JUNE - N. 18 57 PROTECTIVE COATINGS | INNOVATIONS © Belzona 5 Acid tanks, outer view. Serbatoi di acido, esterno. 5 and inspected recently, revealing that the Belzona protection was fully intact. 100% solids epoxy materials adhere well not only to concrete, but can be successfully used to protect a metal substrate from the chemicals. Added flexibility of the coating expands and contracts in sympathy with the underlying metal substrate. This second case study comes from China, where Belzona 4361’s chemical resistance and flexibility were put to the test when it was used to line two acid tanks at an oil field’s power plant (Fig. 5). The acid tanks contain 37% hydrochloric acid and were previously protected with an elastomer lining. In winter, when the plant transferred the hydrochloric acid from cold environment (<-0°C/32°F) to room temperature (>20°C/68°F), the dramatic temperature change caused the existing elastomer lining to crack and, as a result, the tanks started leaking. Belzona 4361 was used to line two tanks in October 2015 (Fig. 6) and the client requested another two tanks to be coated in 2016. Utilising coatings which provide chemical resistance as well as crack-bridging ability is crucial to both comply with relevant standards and to guarantee lasting protection from spills. As the industry keeps improving the safety of their operations, material manufacturers need to keep up and continue to innovate by utilising novel raw materials. Of course, provision of an adequate secondary containment area is only one of the many 58 N. 18 - 2016 JUNE - ipcm® Protective Coatings ta nel marzo 2015 e ispezionata recentemente: la protezione di Belzona era ancora completamente intatta. I materiali epossidici 100% solidi aderiscono bene al cemento ma posso essere usati con successo anche per proteggere le superfici in metallo dalle sostanze chimiche. Il rivestimento flessibile si espande e contrae insieme al metallo che ricopre. Il secondo caso di successo viene dalla Cina, dove la flessibilità e la resistenza di Belzona 4361 sono stati messi alla prova quando il prodotto è stato usato per rivestire due serbatoi di acido in una centrale elettrica a petrolio (fig. 5). I serbatoi di acido contengono acido cloridrico al 37% e in precedenza erano stati protetti con un rivestimento elastomerico. In inverno, quando l’impianto ha trasferito l’acido cloridrico dall’ambiente freddo (<-0°C/32°F) a temperatura ambiente (>20°C/68°F), lo sbalzo drastico di temperatura ha causato la frattura del rivestimento elastomerico, causando la fuoriuscita di materiale dai serbatoi. Belzona 4361 è stato usato per rivestire questi serbatoi a ottobre 2015 (fig. 6), e il cliente ha richiesto il rivestimento di altri due serbatoi per il 2016. L’utilizzo di rivestimenti che offrono sia resistenza chimica sia proprietà di crack-bridging è cruciale sia per essere conformi agli standard più importanti sia per garantire una protezione duratura contro le perdite. Mentre l’industria continua a migliorare la sicurezza delle operazioni, i produttori di materiali devono stare al passo e continuare a innovare utilizzando nuove materie prime. Naturalmente, disporre di un’area di contenimento secondario è soltanto uno dei miglioramenti Marina Silva Belzona Polymerics Ltd, Harrogate UK, [email protected] 6 Belzona 4361 applied. © Belzona Belzona 4361 applicato. 6 improvements that can be done to manage hazards and minimise risks. Some of the other areas to consider include system automation and software, with leak detection technologies and alarm sounding. Such systems can dramatically reduce human error, which was found to be a major contributing factor in the progression of several accidents described in the Seveso Directive. Enhancing safety protocols will ultimately ensure that accidents such as Buncefield do not happen again. ‹ che si possono effettuare per gestire i pericoli e minimizzare i rischi. Alcune tra le altre aree da considerare includono i sistemi di automazione e i software, con tecnologie di rilevamento delle perdite e allarmi sonori. Sistemi come questi possono ridurre drasticamente l’errore umano, una delle cause principali di diversi incidenti descritti nella Direttiva Seveso. Il miglioramento dei protocolli di sicurezza assicurerà infine che incidenti come quello di Buncefield non accadano di nuovo. ‹ References: References: 1. Broder, M.F., Technical Report: Building a Secondary Containment System, United States, Tennessee Valley Autority, 1994 2. Rivers, K., Buncefield Standards Task Group Final Report: Safety and Environmental Standards for Fuel Storage Sites, http://www.hse.gov.uk/comah/buncefield/ bstgfinalreport.pdf, 2007 (Accessed on 1 January 2016) 3. European Commission, The Seveso Directive, http://ec.europa.eu/environment/ seveso/, 2015 (Accessed on 10 December 2015) 4. 40 CFR 264.193 – Containment and Detection of Releases, https://www.law. cornell.edu/cfr/text/40/264.193, 2015 (Accessed on 20 December 2015) 5. Grainger, W. W., Secondary Containment Requirements: Quick Tips, https://www. grainger.com/content/qt-secondarycontainment-requirements-182, 2015, (Accessed on 20 December 2015) 6. Water Resources, England, The Control of Pollution (Oil Storage) (England) Regulations 2001, http://www.legislation.gov.uk/uksi/2001/2954/pdfs/ uksi_20012954_en.pdf, 2001, (Accessed on 20 December 2015) 7. NCC Bund Lining, Bund Lining Materials, http://www.bundlining.co.uk/ BundLiningMaterials.html, 2014 (Accessed on 10 January 2016) 1. Broder, M.F., Technical Report: Building a Secondary Containment System, Stati Uniti, Tennessee Valley Autority, 1994 2. Rivers, K., Buncefield Standards Task Group Final Report: Safety and Environmental Standards for Fuel Storage Sites, http://www.hse.gov.uk/comah/buncefield/ bstgfinalreport.pdf, 2007 (accesso l’1 gennaio 2016) 3. Commissione Europea, The Seveso Directive, http://ec.europa.eu/environment/ seveso/, 2015 (accesso il 10 dicembre 2015) 4. 40 CFR 264.193 – Containment and Detection of Releases, https://www.law. cornell.edu/cfr/text/40/264.193, 2015 (accesso il 20 dicembre 2015) 5. Grainger, W. W., Secondary Containment Requirements: Quick Tips, https://www. grainger.com/content/qt-secondarycontainment-requirements-182, 2015, (accesso il 20 dicembre 2015) 6. Water Resources, Inghilterra, The Control of Pollution (Oil Storage) (England) Regulations 2001, http://www.legislation.gov.uk/uksi/2001/2954/pdfs/ uksi_20012954_en.pdf, 2001, (accesso il 20 dicembre 2015) 7. NCC Bund Lining, Bund Lining Materials, http://www.bundlining.co.uk/ BundLiningMaterials.html, 2014 (accesso il 10 gennaio 2016) ipcm® Protective Coatings - 2016 JUNE - N. 18 59
Documenti analoghi
protective coatings | innovations
final dimension.
2.7.2 Sealing
Sealing sprayed coatings
serves primarily to fill the
pores and microcracks
in the coating, which
provides additional
protection against
corrosive media that
protective coatings | innovations
per ripristinare le dimensioni originali dei componenti (fig. 26). I rivestimenti possono essere torniti o rettificati alla dimensione finale. Ni-Cr, Ni-Al o
Ni-Cr-Al sono utilizzati come materiali...