dulux trade paints
Transcript
dulux trade paints
N T E G R A T I O N RCHITECTURE Openable window: Aluminium thermally seperated framed double glazed unit with opening lights. Double glazed argon filled with low E glass. Window: Aluminium thermally seperated framed double glazed unit with opening lights. Double glazed argon filled with low E glass. Colour/finish to clients requirements. Mechanical ventilation to shower room to be capable of extracting air at a rate of not less than 15 litres per second providing 3 air changes per hour operated intermittently. Linked to light switch to provide 20 minute over run with 100m dia ducting as shown. WASH BASIN: TO SHOWER ROOM. - Wash basin: Ideal Standard Studio Semi-countertop Basin, - Size: 560x460mm, 1 tap hole. - Supplier: Ideal Standard. - Material: Vitreous China. - Colour: White. - Fixings: As standard. - Taps: For high water pressure, requires min 1 Bar : Use Single Lever Mono Basin Mixer. For low water pressure, 0.2 Bar: Use Economy Single Lever Basin Mixer. - Supplier: Home of Ultra Eon. - Material: Chrome. WC PAN AND CISTERN: TO SHOWER ROOM. - Pan: Envy Wall Hung WC HO Ref. NV1738 - Material: Vitreous China. - Seat and cover: Envy Seat and Cover Top Fix hinge Ref. NV7855 - Supplier: Twyford. - Cistern: Cistern Assembly BSIO Duct 6L. 14X9 Flushbend. Ref. CX9160XX. - Fittings: SR8138XX galerie w/hung wc/bidet bracket & bolts assembly WF1240WH pan connector 'p trap. CF3018CP lever assy-extended 240 wall. - Sealing: Silicone sealant at junction of cistern with cistern enclosure. - Colour: White. 100mm Iso Spray Foam strictly to manufacturers recommendations 12mm marine plywood sheets screw fixed to studwork Service zone Preservative treated sw studs/blocking as required 12mm thick 1200x900mm cement based tile backer boards to all walls of shower room with Altro 2.5mm non-slip vinyl floor finish and Altro vinyl wall finish having coved skirting junctions between floor and wall finishes. 300mm wide x 1000mm high moisture resistant mirror with flat polished edges and 380mm long vanity light above with shaver socket 22mm thick T&G flooring quality chipboard sheets. All edges to be supported. Sheets to be screw-fixed at 300mm c/c to treated battens below Skirting trim Treated softwood 50mm wide, depth to requirements @ 400mm c/c on insulation seperating layer DETAILED SECTION A-A SHOWER Container subfloor Telivision and tv socket and switch, etc. 100mm Iso Spray Foam strictly to manufacturers recommendations 1981X610mm solid core door leaf 100mm Iso Spray Foam strictly to manufacturers recommendations A A 37.5mm Kingspan K18 to inner face of the metal studs with a minimum 3mm plaster skim. 100mm deep metal studs at 400mm c/c Altro Aquarius floor finish, thickness 2mm, to bedroom and shower room with coved upstand skirtings. Colour to clients requirements 565mm EMULSION PAINT TO WALLS AND CEILINGS TO BEDROOM - Manufacturer: ICI Dulux Trade Paints. - Paint type: Dulux Trade Diamond Matt - Surface(s): New plaster skimmed ceilings and walls generally. - Preparation: To be applied to smooth properly prepared surfaces - Initial coat(s): Strictly to manufacturers recommendations. - Finishing coats: Strictly to manufacturers recommendations. - Colour.: To clients requirements Twin switched 13A socket outlet Work desk LED Eco-Lite LED Surface mounted ceiling light 17 watt LED light bulb. Product Ref: LE099. Colour: White cover with silver sides Work voltage: AC85-265 Volt. PF:>85%, CRI:>75 50-60Hz Diameter: 314mm, depth: 80mm. 1 A-002 SD Clothes hanging area and shelf above. 2 A-002 Openable window: Aluminium framed (colour to clients requirements) to be double glazed window Min mid pane 'U' value of 1.5W/m2K or better. Glazing to be clear toughened safety glass in hermetically sealed double-glazed units with low 'E' coating and argon filled cavity. Windows to have min 1/20th floor area as opening lights. 500mm wide skirting to ceiling impact resistant mirror with flat polished edges DETAILED FLOOR PLAN 100mm Iso Spray Foam strictly to manufacturers recommendations 900x900mm shower tray CYR5046/28LE Cyro Low energy moisture resistant bathroom light fitting (OF3848LE) Smoke detector to be self contained and mains operated with battery back-up and conforms to BS 5839-6:2004. 37.5mm Kingspan K18 to inner face of the metal studs with a minimum 3mm plaster skim. Altro Aquarius floor finish, thickness 2mm, to bedroom and shower room with coved upstand skirtings. Colour to clients requirements Mira Sport Electric Shower 9.0kW - White/Chrome 12mm thick 1200x900mm cement based tile backer boards to all walls of shower room with Altro 2.5mm non-slip vinyl floor finish and Altro vinyl wall finish having coved skirting junctions between floor and wall finishes. Window: Aluminium framed (colour to clients requirements) to be double glazed window Min mid pane 'U' value of 1.5W/m2K or better. Glazing to be clear toughened safety glass in hermetically sealed double-glazed units with low 'E' coating and argon filled cavity. Windows to have min 1/20th floor area as opening lights. Architecture 12 Crummock Gardens, The Hyde, London NW9 0DG. Tel: 020 8200 7758 Email: [email protected] DETAILED ELEVATION 1 DETAILED ELEVATION 2 EMULSION PAINT TO SHOWER ROOM CEILING. - Manufacturer: ICI Dulux Trade Paints. - Paint type: Dulux Trade Bathroom Paints. - Surface(s): New plaster skimmed ceilings and walls generally. - Preparation: To be applied to smooth properly prepared surfaces - Initial coat(s): Strictly to manufacturers recommendations. - Finishing coats: Strictly to manufacturers recommendations. - Colour: To clients requirements Integration 838mm wide glazed exterior quality metal door. Double glazed argon filled with low E glass and thermally seperated metal door frame. U Value Exterior Entrance Door: 2.0Wm2 GLAZING IN CRITICAL LOCATIONS: All glazing in critical areas such as: 1. Glazing up to 800mm above floor level in internal and external walls and partitions and all glazing panels where part of the panel is within this dimension. 2. Glazing up to 1500mm above floor level in a door or side panel within 300mm of the door and all glazing panels where part of the panel is within this dimension should be fitted with safety glass to BS 6206:1981 EXTERNAL WINDOWS: Aluminium framed (colour to clients requirements) to be double glazed window Min mid pane 'U' value of 1.5W/m2K or better. Glazing to be clear toughened safety glass in hermetically sealed double-glazed units with low 'E' coating and argon filled cavity. Windows to have min 1/20th floor area as opening lights. ELECTRICAL: The competent persons scheme must be used. All wiring and electrical work must be designed, installed, inspected and tested in accordance with the requirements of BS7671, the IEE 17th edition Wiring Guidance and Building Regulation Part P (electrical safety) by a person who is a member of the Competent Person Scheme authorised by the Secretary of State. AND The person who is a member of the Competent Persons Scheme is to send to the local authority a self-certification certificate within 30 days of the electrical works completion. The client must receive both a copy of the self-certification certificate and a BS7671 Electrical Installation Test Certificate. Client 2012 OLYMPIC LIVING. 637a Romford Road Newham, London, E12 5AD Project 2012 OLYMPIC LIVING. FOREST ROAD, BARKING, ESSEX. Drawing Title DETAILED VIP ROOM PLAN ELEVATIONS AND SECTION A-A Scale Job no. 12001 Date 240 Volt 3-phase supply 1:25 at A2 Size Jan 2012 SMOKE DETECTORS: smoke detectors as shown on floor plans to be self contained and mains operated with battery back-up and conforms to BS 5839-6:2004. Drawing no. Status & Rev – P / A Internal Lighting to be low energy. MECHANICAL VENTILATION: Mechanical ventilation to shower room, to be capable of operated intermittently, linked to light switch to provide 20 minute over run. To have 100m dia ducting. To part F of the Building Regulations. POSITIONING OF POWER POINTS ETC. Twin 13Amp switched socket outlet to desk. Provide 13Amp switched electrical socket for television and supply tv aerial socket. Wall mounted socket outlets, light switches, tv sockets, etc to be located between 450mm and 1000mm above floor level. MISC NOTES: * Structural timber to be C16 grade unless otherwise stated. * NOTE: All timber studs, blocking, etc to be preservative treated * An Electrical Certificate must be provided upon completion of the works. General Notes Jan 2012 This drawing is the copyright of Integration Architecture. All dimensions to be checked on site. Do not scale. All levels to be checked on site and refer to Ordnance Survey Datum Newlyn unless alternative datum given. All errors and omissions to be reported to the Architect prior to commencement. This drawing must be read in conjunction with the relevant specification clauses. This drawing must not be used on site unless issued for construction. Status: R = Record. P = Preliminary. Pl = Planning. B = Building Control. T= Tender. C = Construction.
Documenti analoghi
PDF details - McCartneys
with four/ five bedrooms (depending on user
requirements) arranged over two floors with a
fantastic breakfast kitchen extension to the rear.
A must see property with
accommodation to comprise:-