Avery Hardoll-Isoil Interchangeability

Transcript

Avery Hardoll-Isoil Interchangeability
Avery Hardoll-Isoil
Interchangeability
Data sheet: DS/CO/0006/EN Ed. May 2015
PD Meters
Isoil meters are fully compatible
with almost all Avery Hardoll series
meters allowing one to one
replacement.
Specifically here the matching
table:
Avery Hardoll meters
Avery Hardoll BM250 BM950 BM450 BM550 BM350 BM650 BM750 BM850 CM1000 CM1400 CM2000 CM2500 CM3000 CM4000 Flow rate 115‐1140 L/min. 130‐1370 L/min. 200‐2050 L/min. 220‐2280 L/min. 250‐2500 L/min. 300‐3000 L/min. 300‐3000 L/min. 387‐3870 L/min. 100‐1000 L/min. 140‐1400 L/min. 200‐2000 L/min. 250‐2500 L/min. 300‐3000 L/min. 400‐4000 L/min. Isoil meters
(1)
Connection 21/2” 356 mm. 3” 356 mm. 3” 400 mm. 4” 400 mm. 4” 400 mm. 4” 400 mm. 6” 400 mm. (4) 6” 400 mm. (4) 21/2” 356 mm. 3” 356 mm. 4” 400 mm. 4” 400 mm. 6” 400 mm. (4) 6” 400 mm. (4) Isoil BM200 BM200 BM400 BM400 BM400 BM600 BM600 BM600 BM200 BM200 BM400 BM400 BM600 BM600 Flow rate 100‐1500 L/min. 100‐1500 L/min. 200‐2600 L/min. 200‐2600 L/min. 200‐2600 L/min. 300‐4000 L/min. (3) 300‐4000 L/min. (3) 300‐4000 L/min. (3) 100‐1500 L/min. 100‐1500 L/min. 200‐2600 L/min. 200‐2600 L/min. 300‐4000 L/min. (3) 300‐4000 L/min. (3) (1)
Connection 3” 356 mm. 3” 356 mm. 4” 400 mm. (2) 4” 400 mm. (2) 4” 400 mm. (2) 6” 400 mm. (4) 6” 400 mm. (4) 6” 400 mm. (4) 3” 356 mm. 3” 356 mm. 4” 400 mm. (2) 4” 400 mm. (2) 6” 400 mm. (4) 6” 400 mm. (4) Notes:
(1). Connection means size of ANSI150 flanges and flange to flange dimension
(2). 430 mm version available. Specify the version needed on order phase
(3). 200-4000 L/min. Version on request
(4). Aluminium manifold standard, carbon steel on request
ISOIL IMPIANTI S.p.A
A. - 24061 Albano S. Alessandro (BG) - Italy
tel: +39.02.91988.5
fax:: +39.02.66012457
web:www.isoilmeter.com e-m
mail: [email protected]
DS/CO/0006/EN - 05//2015
Pag. 1/2
Electronic counter VegaT is a modern device with full keyboard, full backlighted
graphic display and a single Atex approved case where no
extra box is necessary.
VegaT can replace easily the actual MasterLoad present in the
market thanks to its panel mounting installation and pulse
emitter retrofit kits for Avery Hardoll BM and CM series.
VegaT
Additionally a keyboard mask can be used as a “two button”
operation for who it is used to have a simplify approach to the operation. VegaT includes a full display information including totalizer, rate
of flow indication plus a specific prompt area and extra field at
customer choice.
Finally yet importantly, it includes a full 10 points calibration
curve to optimise meters accuracy.
VegaT enjoy the compatibility with the main On Board
Computer system actually used into various Airports. Please
contact us for having full list of system supported.
Master load
VegaT with
key board mask
CM and BM Avery Hardoll meters
with Isoil EM6422 pulse emitter
ISOIL IMPIANTI S.p.A
A.- 24061 Albano S. Alessandro (BG) - Italy
tel: +39.02.91988.5 fax:: +39.02.66012457
web:www.isoilmeter.com e-m
mail: [email protected]
DS/CO/0006/EN - 05//2015