ProDRiS - DICA - Politecnico di Milano
Transcript
ProDRiS - DICA - Politecnico di Milano
POLITECNICO DI MILANO Dipartimento di Ingegneria Civile e Ambientale Department of Civil and Environmental Engineering Sezione ProDRiS Progettazione, Diagnostica e Riabilitazione Strutturale Structural Design, Diagnostics and Rehabilitation ProDRiS – Faculty Staff 1 PO – Professors (4); 2 PA – Associate Profs (2); 2 3 RI – Assistant Profs (6) + 10 Research Fellows Fabio Biondini 2 Matteo Bruggi 3 Giuliana Cardani 3 Paola Condoleo 3 Dario Coronelli 3 Elsa Garavaglia 2 Maurizio Lualdi 3 Pier Giorgio Malerba 1 Gianpaolo Rosati 1 Alberto Taliercio 1 Cristina Tedeschi 3 Luigi Zanzi 1 Scientific Coordinator Sezione ProDRiS ProDRiS – Research Areas 3 Theory and Methods of Structural Design • Structural Analysis • Structural Reliability • Structural Optimization • Life-Cycle Design Survey, Inspection, Monitoring and Structural Diagnostics • Built Heritage • Non Destructive Testing (NDT) • Geophysical Prospections Design of New Structures and Rehabilitation of Existing Structures • Materials and Structures • Bridges and Buildings • Maintenance and Safety of Existing Structures • Fastenings and Connections Sezione ProDRiS ProDRiS – Research Areas 4 Theory and Methods of Structural Design • Structural Analysis • Structural Reliability • Structural Optimization • Life-Cycle Design Survey, Inspection, Monitoring and Structural Diagnostics • Built Heritage • Non Destructive Testing (NDT) • Geophysical Prospections Design of New Structures and Rehabilitation of Existing Structures • Materials and Structures • Bridges and Buildings • Maintenance and Safety of Existing Structures • Fastenings and Connections Sezione ProDRiS Theory and Methods of Structural Design 5 Time-evolution of damage in historical buildings 2008: ‘numerical collapse’ AD 1591 1691 1900 1800 Creep-induced damage in Pavia belltower (†1989): numerical prediction Sezione ProDRiS Prediction of crack evolution in San Vitale Basilica via XFEM Theory and Methods of Structural Design 6 Prediction of the macroscopic mechanical properties of brickwork Deformed unit cell under normal stress (a) or shear (b) unit cell (a) Macroscopic Young’s and shear moduli vs joint thickness Sezione ProDRiS (b) Macroscopic creep curves under normal stress and shear Theory and Methods of Structural Design 7 Topology optimization applied to thermal insulation Optimized block sections for different out-of-plane compliances Typical commercial masonry blocks heat flux Influence of shear keys on optimal design Sezione ProDRiS Gain in thermal transmittance: Indented blocks Smooth blocks Theory and Methods of Structural Design 8 Finite element analysis of no-tension structures Formulation of an energy-based method to distribute and orientate an ad hoc orthotropic material that behaves as a compression-only medium Investigation on the behavior of masonry structures in terms of both stresses and displacements: - at the serviceability limit state (SLS) - at incipient collapse (US) Principal stresses at SLS (p=0) Deformed shape, expected collapse mechanism and principal stresses at US Sezione ProDRiS Theory and Methods of Structural Design 9 Optimal fiber-reinforcement of existing structures Formulation of an optimization method to distribute and orientate an available amount of unidirectional fiberreinforcement (FRP) such that in-plane stresses are feasible with a Tsai-Wu strength criterion governing the underlying anisotropic layer. Plain/reinforced concrete and brickwork can be dealt with Optimal distribution and orientation of FRP strips for an architrave subject to horizontal loads Sezione ProDRiS Theory and Methods of Structural Design Topology optimization including displacement and stress constraints Optimal design of truss-like structures for minimum weight subject to displacement and stress constraints, including non-symmetric behavior of the material in tension and compression (Drucker-Prager) Optimal design and relevant D-P stress maps for three optimization strategies with s=2/3: a) displacementconstrained, b) stress-constrained, c) displacementand stress- constrained Sezione ProDRiS 10 Theory and Methods of Structural Design 11 Topology optimization of micro-structured media under dynamic loads Optimal design for maximum dynamic stiffness of Cosserat media, investigating the effect of the microstructure on the achieved optimal layout Deep cantilever with two masses A new material model to penalize stiffness and mass on the design unknowns without numerical instabilities Transition from truss-like to beam-like layouts, for increased values of the characteristic length of the material Sezione ProDRiS Theory and Methods of Structural Design 12 Structural Optimization and Conceptual Design Adaptive Evolutionary Process Static Evolutionary Process Sezione ProDRiS Theory and Methods of Structural Design 13 Optimal Strut-and-Tie Models for Concrete Structures φ6/225 2φ10 (0) Linear Elastic (p0) Cracked (p1) SezioneNonlinear ProDRiS Nonlinear Cracked (p2>p1) Nonlinear Cracked (p3>p2) Nonlinear Cracked (p4=pu) Theory and Methods of Structural Design 14 Form finding and structural optimization Form finding in cable nets. Application of the Force Density Method A bridge with two set of cables in two inclined planes Optimal solution for a large cable roof (displacement scale factor =20%) CABLE STRUCTURES • Form finding; • Internal mechanisms and prestressing distribution evaluation; • Structural optimization (genetic algorithms); • Applications: cable roofs, cable domes, cable beams, footbridges with new forms. Internal mechanism in a Geiger dome Sezione ProDRiS Theory and Methods of Structural Design 15 Nonlinear and Limit Analysis of Concrete Structures Nonlinear Analysis Limit Analysis Fan Semifan Harp Type λ pu1 = g+λq [kN/m] Nonlinear Analysis pu2 [kN/m] Fan 9.14 429 300 0.70 Semifan 8.41 403 300 0.74 Harp 5.97 315 220 0.70 Limit Analysis Sezione ProDRiS Effectiveness Factor cracked concrete concrete at failure (εc ≈ εcu) pu2 / pu1 Effectiveness Factor (system level) ν c = 0.5 + 1.25 fc = 0.71 Theory and Methods of Structural Design 16 Markovian approach in reliability assessment and maintenance planning P∆(ijt t)0 = [ Fij (t0 + ∆t ) − Fij (t0 ) ] pij µ (t , k ) = (1 − δ (t , k ) ) ⋅ s ∑ [ 1 − Fik (t0 )] pik Rk (t ) − S k (t ) Rk (t ) k =1 Conditional probability different states. of transition through Condition index as suitable life-cycle indicator for the selective maintenance. Selective maintenance scenarios 1.0E-03 1.0 0.9 Condition index µ P(m,0j)∆t|t0=1yr 8.0E-04 6.0E-04 4.0E-04 2.0E-04 d 0.8 0.7 0.6 0.5 0.4 µ =0.40 0.3 0.2 0.0E+00 0 5 10 15 20 25 30 35 40 45 50 8 6 0.1 0 10 20 30 Time [years] instant of maintenance 1.20 1.10 n Cq q =1 (1 + v) q Cm = ∑ n t m = ∑ C0 q q =1 C q = C f + ∑ δ k ⋅ Vk ⋅ cqk k =1 Total cost Cm=C2, of the scenario (2) normalized to the cost C1 of the scenario (1). Cq is the sum of initial cost C0 and replacement cost C(1,m), of the scenario (2) normalized to the cost C1 of the scenario (1), for different values α of the fixed cost of maintenance Cf =α C0. Normalized cost c Cost analysis applied to different scenarios 1.00 0.90 0.80 (1) (2) (2) (2) (2) (2) (2) 0.70 0.60 0.50 0.00 0.02 0.04 0.06 Discount rate n Sezione ProDRiS 0.08 a =0.00 a =0.05 a =0.10 a =0.15 a =0.20 a =0.25 0.10 9 10 40 50 Theory and Methods of Structural Design Life-Cycle Assessment and Design of Bridges and Structures www.ialcce.org | www.iabmas.org www.iabmas-italy.it Certosa Cable-Stayed Bridge 0.150 Yielding Moment my 0.140 0.130 0.120 Damaged Structure 0.110 Rehabilitated Structure 0.100 0.090 0 Sezione ProDRiS 10 20 30 Time [year] 40 50 Theory and Methods of Structural Design 18 Structural Robustness and Seismic Resilience of Bridges and Structures Exposure Scenario Life-Cycle Seismic Performance of a RC Bridge exposed to Corrosion a g (t ) ag0 Time-variant Functionality! Time-variant Resilience under Seismic and Environmental Hazards ROBUSTNESS Q(t ) = R= Sezione ProDRiS 1 t h − t0 ∫ th t0 Q(t )dt ProDRiS – Research Areas 19 Theory and Methods of Structural Design • Structural Analysis • Structural Reliability • Structural Optimization • Life-Cycle Design Survey, Inspection, Monitoring and Structural Diagnostics • Built Heritage • Non Destructive Testing (NDT) • Geophysical Prospections Design of New Structures and Rehabilitation of Existing Structures • Materials and Structures • Bridges and Buildings • Maintenance and Safety of Existing Structures • Fastenings and Connections Sezione ProDRiS Survey, Inspection, Monitoring and Structural Diagnostics Non-destructive testing: high resolution radar applications Objective: development of NDT technologies for Cultural Heritage diagnostics Example of ultra-high frequency radar survey in small spaces between decorations and frescoes on the counterfacade of S.Andrea Basilica in Mantova: 3D radar maps from dual-polarized data detect a vertical metal anchor embedded in the masonry. It is part of a tie-rod system connecting the counterfacade and the facade of the church. Example of radar tomography: horizontal section of a masonry pillar. The radar map demonstrates that the pillar perimeter consists of regular stone blocks while the inner core consists of irregular and poorly cemented stone and brick material. attenuation map high low Sezione ProDRiS 20 Survey, Inspection, Monitoring and Structural Diagnostics 21 Non-destructive testing: high resolution radar applications Objective: development of radar technique for quality assessment of quarried stone blocks Example of 3D radar reconstruction of a defect in a marble block. The defect consists of a clay inclusion that was visible on the top surface of the block. The radar result shows the size and the 3D shape of the clay inclusion. Sezione ProDRiS Example of high frequency 3D radar survey to map ultra-thin cracks and discontinuities in a marble block. Survey, Inspection, Monitoring and Structural Diagnostics 22 Non-destructive testing: high resolution radar applications Objective: development of radar technique for Quality Control of reinforced concrete Example of 3D radar reconstruction of the reinforcement net in a concrete slab. Analysis of radar data in perpendicular and parallel polarization vs. reinforcement diameter: the ratio of energy scattered in orthogonal polarizations shows a behaviour consistent with the radar cross-section theory. A dual-polarized antenna is a promising tool for non-invasive assessment of rebar diameter. Sezione ProDRiS Survey, Inspection, Monitoring and Structural Diagnostics 23 Geophysical Prospections: Civil Protection applications Objective: monitoring unstable rockslopes with microseismic sensor networks Principle of microseismic monitoring with a wireless sensor network. Sezione ProDRiS Example of a microseismic event detected by 5 three-component geophones installed on the unstable rockslope of Mt. San Martino (Lecco). Survey, Inspection, Monitoring and Structural Diagnostics 24 Geophysical Prospections: Civil Protection applications Objective: development of technologies for search and rescue actions Testing a new prototype of microseismic equipment for detection and localization of survivors trapped in building debris. Sezione ProDRiS Example of microseismic noise generated by a survivor and detected by the prototype equipment in the training field of the Search and Rescue team of VVF in Pisa. Survey, Inspection, Monitoring and Structural Diagnostics 25 Vault of Sala dei Mappamondi - Royal Academy of Sciences TORINO Geometrical survey and inspections for determination of the thickness of the vault Mortar sampling for laboratory analyses Sezione ProDRiS Survey, Inspection, Monitoring and Structural Diagnostics Vault of Sala dei Mappamondi - Royal Academy of Sciences TORINO Thermographic investigations Passive thermography was used to identify the shape of the timber structure hidden inside the mortar layers. Active thermography was useful to detect the presence of detachments between the frescoed surface layer of the vault and its internal structure, and to evaluate the crack pattern that may be observed at the intrados of the vault. Stratigraphic surveys, mortar sampling and optical observations. Sezione ProDRiS 26 Survey, Inspection, Monitoring and Structural Diagnostics 27 Repair of masonries by injection of grouts The sample have been injected, in controlled condition of 20°C and 75% RH, using a injector and a pipe connected with a hole at the base of a plexiglas cylinder, so to prevent any pressure loss. The same procedure was used for the prisms Prisms and cylinders were cut into slices and the filled cracks were observed. Images show a penetration and adhesion of the grout to the crack surface Sezione ProDRiS Survey, Inspection, Monitoring and Structural Diagnostics 28 Durability of masonry repaired by CFRP textiles Salt crystallization tests on brick masonry reinforced by CFRP textiles RILEM TC 243 MSC Sample S2a_p1 220 200 180 160 140 120 100 80 60 40 20 0 2 4 8 10 mm 12 Damage measuring device: a) lasers profilometer, b) scheme of the measurement. Moisture and Temperature Influence on FRP Masonry Bonding The proposed artificial ageing was carried out as follows (at 60% RH): a: +20 to +70°C in 1 h (0.8°C/min) b: 3 hours at 70°C c: +70°C to -10°C in 1:30 h (1.0°C/min) d: 3 hours at -10°C e: -10°C to +70°C in 1:30 h (1.0°C/min) Analysis at stereomicroscope showing two types of rupture: a) presence of a border below the fibre at the limit of the impregnated layer; b) b) detachment of the border with failure in the brick Sezione ProDRiS S1_P1 S1_P2 S1_P3 S2a_P1 S3a_P3 S3a_P2 4.0 Loss (%) mm 5.0 6 3.0 2.0 1.0 0.0 1 2 3 4 Cycle 5 6 7 Survey, Inspection, Monitoring and Structural Diagnostics 29 Fragility curves approach for long term behavior and durability assessment εv(x103) 10 K W Ec S B Q M In 0 Laboratory data collection for long behavior assessment W -10 Ec εh(x103) -20 In Q B -30 -40 M S K 0 200000 400000 600000 800000 time [sec] [mm] 0 50 100 150 200 0 MA T0 Cycle I Cycle II Cycle III Cycle IV Cycle V Cycle VI Cycle VII 5 A 15 [mm] 10 20 25 Laboratory data collection for durability assessment 30 F− (c) 1 C 0.9 1.5 1.0 1.5 − =2.5 =1.5 0.8 L(c*, ) 2.0 i(%) 2.0 i(%) 2.5 L(c*, ) 2.5 =2.0 0.7 0.6 =3.0 0.5 0.4 1.0 0.3 0.5 0.5 0.0 0.0 0 1 2 3 4 5 6 Cycles Sezione ProDRiS 7 0.2 0.1 0 1 2 3 4 Cycles 5 6 7 0 0 2 4 6 8 10 12 c (cycles) 14 16 18 20 Survey, Inspection, Monitoring and Structural Diagnostics Durability of the bond between FRP/TRM and masonry substrates 30 [RILEM Tc CSM and RELUIS 2014] Influence of aggressive environmental conditions (moisture, temperature and soluble salts presence) on the bond between FRP/TRM and masonry substrates. Experimental tests (pull-off test) have been carried out on site on full-scale models made in brickwork and lime-stonework at 3 different heights. Sezione ProDRiS Theory and Methods of Structural Design 31 Built heritage: structural survey The bell tower of Arcisate Location of the investigations and summary of the results obtained Survey of the external crack pattern Location of the internal and external profiles on the masonry sections. Magnification of the geometry variation: the profiles that were not surveyed are plotted with dashed lines. Sezione ProDRiS Scheme used to interpret the displacement. Survey, Inspection, Monitoring and Structural Diagnostics 32 Built heritage: structural survey Static behaviour of a double curvature brickwork vault Rigid body motion of the grid of I beams: the grid has undergone a rotation Intrados of the vault Crack pattern of the vault intrados Hanging system: thin metal elements bolted to the beam web Hanging system: flat metal strips wrapped below the beam flange Rigid body motion (in red) and profiles as measured during the geometrical survey (in blue) Cracks are more concentrated on the vault portion with greater curvature, especially where the vault perimeter is not confined by the hallway The direction of diagonal cracks correspond to that of the buttress walls A long crack going E-W is probably due to tensile stress, according to the I iron beam profiles described later Sezione ProDRiS Load-induced displacements (magnified 10 times): symmetrical shapes characteristic of continuous beams, with a rather “flat” center portion Larger vertical displacement probably due to tensile stress Survey, Inspection, Monitoring and Structural Diagnostics 33 Investigation and diagnosis of the built patrimony of historic centres in seismic areas A methodology for the study of vulnerability at large scale: 1. Definition of the building and masonry typology 2. Crack pattern and structural damage survey 3. Use of an abacus and interpretation of the crack pattern 4. Material characterization: laboratory and on site tests (a minimal investigation program is suggested) 5. Seismic vulnerability analysis 6. Choice and analytical assessment of the improvement techniques Isolated building Crack pattern survey also adopting axonometric representations and volumetric stratigraphical analysis, in order to single out their typical failure mechanisms, also in presence of modern or traditional retrofitting techniques. A A' Row building UI 197 Survey template UI 198 UI 199 Complex buildings 2.3 - SCHEMA DEI CINEMATISMI E STATO DI DANNO (anno 2001) DELL'EDIFICIO U.M.I. 10 1 1 2 2 3 2 4 0 1 5m 3 PROSPETTO SUD 1 5 0 1 3 5m PROSPETTO NORD 1 Danno: lesioni diffuse in corrispondeza delle teste delle travi di copertura. 1 Meccanismo: martellamento degli elementi di copertura per spinta fuori piano. 2 Danno: lieve spanciamento della parete con lesioni pressocchè verticali in corrispondenza degli elementi di differente rigidezza. 2 Meccanismo: spinta fuori dal piano della parete sud a causa della particolare conformazione della pianta, della disomogeneità del tessuto murario, e della spinta delle travi del solaio. 3 Danno: lesione verticale in corrispondenza dell'attacco dei due edifici. 3 Meccanismo: risposte differenziate all'azione sismica degli edifici adiacenti; nel punto di collegamento, che è la zona più debole, si presenta una concentrazione di sforzi di trazione che porta alla rottura del collegamento stesso. 4 Danno: lesione nel maschio snello 4 Meccanismo: schiacciamento dell'elemento snello per forze nel piano della parete. 5 Danno: lesione in prossimità dell'angolata 5 Meccanismo: distacco tra i muri d'ambito per interazione di forze agenti sulle pareti ortogonali. Sezione ProDRiS Application of simply kinematics models to describe the mechanical behaviour Survey, Inspection, Monitoring and Structural Diagnostics Historic masonry quality evaluation with NDT and MDT 34 [RELUIS 2014] A necessary methodology for the quality evaluation of historic load-bearing STONE masonry with visual inspection and using the test results based on Non-Destructive Techniques. With the help of an optical system, the double flat-jack test is able to show in real time the distribution of the forces in the irregular masonry specimen, showing stones rotation and where tensile stress is higher and so cracks are forming. Other complementary ND tests have to be evaluated to understand the intrinsic “ductility” of that poor masonry. 1.20 2 000 1 900 SU-PM-J1D 6 LVDT 1 1 800 LVDT 2 LVDT 4 Sforzo [N/mm2] LVDT 5 2 0.80 5 4 3 4 1 LVDT 3 2 1 700 7 3 1 600 1 500 1 400 1 1 300 1 200 1 100 1 000 Pietra 6-4 900 3 0.40 800 Pietra 3-7 700 pietra 5-2 600 Stato di sforzo locale 500 400 300 0.00 εv εl 2 5 200 100 0 -2.00 -1.00 0.00 1.00 2.00 Deformazione [µm/mm] Sezione ProDRiS 0 200 400 600 800 1000 1200 1400 1600 Survey, Inspection, Monitoring and Structural Diagnostics 35 Building Information Modelling BIM applied to Built Heritage [PRIN 2013-15] Evaluation of the use of BIM for the design and the documentation of built heritage in the restoration process. The interoperability among BIM (Revit or ArchiCad) and structural analysis software is evaluated, as well as the documentation of the crack pattern, the improvement of the calculation model with the introduction of the crack pattern and the creation of a control system of NDT data and monitoring tests results. BIM as a crack pattern documentation and crack pattern exported in Abaqus Export/import procedure results of two simple testing models with different format. Sezione ProDRiS Example of virtual sensor placed on the model and its records ProDRiS – Research Areas 36 Theory and Methods of Structural Design • Structural Analysis • Structural Reliability • Structural Optimization • Life-Cycle Design Survey, Inspection, Monitoring and Structural Diagnostics • Built Heritage • Non Destructive Testing (NDT) • Geophysical Prospections Design of New Structures and Rehabilitation of Existing Structures • Materials and Structures • Bridges and Buildings • Maintenance and Safety of Existing Structures • Fastenings and Connections Sezione ProDRiS Design of New Structures and Rehabilitation of Existing Structures 37 Advanced Cement-Based Materials 40 45SE28-1 45SE28-2 45SE28-3 σ (MPa) 30 20 10 0 0 2 4 ε %o 6 8 Compressive behavior of Self-Compacting Concrete 210 150 105 Ø24 Ø16 48 32 72 SCC UNBONDED LENGTH 24 16 UNBONDED LENGTH 24 8 16 Ø8 SCC UNBONDED LENGTH SCC Effect of size in the bond behavior of Self-Compacting Concrete Thermal degradation of fiber reinforced extruded materials Structural behavior of Self-Compacting Concrete Filled Tubes Sezione ProDRiS 10 Design of New Structures and Rehabilitation of Existing Structures 38 Post-installed fastenings for use in concrete Simulated seismic crack movement conditions τ = τ (Δ𝑇𝑇,Δ𝑡𝑡, 𝑇𝑇𝑚𝑚𝑚𝑚𝑚𝑚 , 𝑡𝑡) 13 12 11 10 9 fb,test (N/mm²) 8 fb,test 7 6 T11 fb,m=a.θ-b 5 4 t1 3 2 1 θmax θk 0 0 θ50 min 100 150 200 250 300 350 Temperature (°C) Fire resistance of post-installed rebars: decay of bond strength as a function of temperature and exposure time Sezione ProDRiS Post-installed fastenings under seismic action Design of New Structures and Rehabilitation of Existing Structures 39 Structural and non-structural use of glass Mechanical behaviour of point fixing devices: experimental and numerical analyses Flexural and lateral torsional buckling experimental investigation of glass beams Sezione ProDRiS Influence of ambient condition on viscous behaviour of laminated glass Design of New Structures and Rehabilitation of Existing Structures 40 Wood connections with three-dimensional nailing plates Behavior under monotonic and cyclic loading Three dimensional nailing plates for structural use in wood connections: angle brackets, joist hangers, post bases, hold downs Behaviour of dowel-type fasteners Joist Hangers: experimental investigation Sezione ProDRiS Angle Brackets: experimental investigation and enhancement in analytical model Design of New Structures and Rehabilitation of Existing Structures 41 Seismic Design and Retrofitting of Precast Structures 2001-2003 ECOLEADER ELSA/JRC, Ispra Sezione ProDRiS 2003-2006 GROWTH 2009-2012 SAFECAST 2012-2015 SAFECLADDING Design of New Structures and Rehabilitation of Existing Structures 42 Natural Hazards vs decision-making processes in buildings life-cycle management Network diagram explaining potential connection between Structural Design Function and vulnerability parameters. Poisson Energy Theory Prof. Imagawa, Denk Univbersity, Tokyo, Japan Natural conditions Social environments Fy {M x ; S y ; Lz ; J n ; Cα ; Dβ ; Eγ } ≥ Required performances Past and present designs This theory establishes an interdependent connection between the main features that define a building and its performance under external loading conditions. Development of a new cognitive function: relation between the main parameters that define an optimal intervention strategy (structural performance, sustainability, funds). Safety optimisation Building heritagepreservation Human life safeguard Material resourcesoptimisation GSM { Pxy ; S z ; Fα } ≥ Environmental preservation Energy efficiency Cost optimisation Funds management andrationalisation Sezione ProDRiS Design of New Structures and Rehabilitation of Existing Structures 43 Testing, Modelling and Design of R/C slabs Testing and modelling of voided slabs Punching Tests LPMSC Politecnico di Milano Nonlinear analysis of flat slabs for gravity and lateral actions Pushover and Nonlinear Time History Analysis of Flat slab floors NLFE Modelling (Abaqus) Voided Slabs (Daliform) Sezione ProDRiS Grid model (Coronelli, 2010) Design of New Structures and Rehabilitation of Existing Structures 44 Analysis and monitoring of the Duomo di Milano Limit Analysis of the cathedral of Milan FE modelling of foundation soil and settlement monitoring 3D FE analyses NLFE Modelling (Abaqus) Study of the geometry and loads Structural models Limit analysis Monitoring (Veneranda Fabbrica del Duomo) Sezione ProDRiS Design of New Structures and Rehabilitation of Existing Structures 45 Residual bearing capacity of riveted steel ties deformed by the swelling of interstitial rust ν = 0,5 Pressure/displacement relationships for an axial force ν=N/Nyelding=0,5: (a) cosinusoidal pressure profile; (b) sinusoidal pressure profiles; (c) F.E. solution without section reduction due to the rivet hole; (d) F.E. solution with section reduction due to rivet hole . Sezione ProDRiS Design of New Structures and Rehabilitation of Existing Structures 46 Integral Bridges – An Integral Bridge for A380 Transit The West Bridge under construction. Cross section of the West Bridge. Relative proportions among bridge, aircraft and railway. Displacement fields for different positions of the aircraft. Sezione ProDRiS Deformed configurations for the heaviest loading conditions.
Documenti analoghi
a study on seismic behaviour of masonry towers - Unitn
Historical masonry towers (bell towers, civic towers, tower-houses,
defense towers on the city walls…) are found throughout the entire
Italian peninsula, where they represent a distinctive feature ...